Verified Laboratory Record

Bacteriostatic Water

This public record confirms the current status and official metadata associated with the laboratory report below. The downloadable PDF remains the primary document of record for archive, review and verification.

Report ID

SYN-2026-005051
Verified

Official laboratory record

This record is active and matches the issued laboratory report.

Verification Summary

Official Record

Report ID
SYN-2026-005051
Status
Verified
Analysis Date
28 Jul 2026
Issued
29 Jul 2026
Verification Key
VK-F69R-E9YB

Sample Information

Verified Sample

Sample
Bacteriostatic Water
Strength
10ml
Batch
PC-BC10-0822P
Cap / Crimp Color
transparent blue / Silver
Manufacturer
PepticoreAminos
Form
White powder in a glass vial
Sample Submission
Sample provided by customer
Received Date
13 Jul 2026
Client
www.pepticoreaminos.net

Analytical Results

Reported Values

Primary values from the official record
Identity
Bacteriostatic Water

Methodology

Analysis Method

Standard Peptide Purity, Mass & Additional Testing

HPLC-UV: High-Performance Liquid Chromatography with Ultraviolet detection. Additional testing includes bioburden screening, endotoxin analysis and heavy metals assessment.

Authorization

Electronic Authorization

Electronically signed by Martin Saar
Date: 2026-07-29 17:04:08 UTC

Comments

Laboratory Notes

Results indicate that the sample meets the defined analytical specifications for identity, purity and impurity profile using the applied RP-HPLC-UV method.

Supplemental Data

Technical Appendix

Expanded technical sections for reference
Bioburden
Detailed Laboratory Data

Bioburden

Test Result Unit Uncertainty Reporting Limit
Total Aerobic Microbial Count
USP <61>/Eur. Ph. 2.6.12. Plate Count Method
Not detected CFU/g — >= 1000
Total Yeast and Mold Count
USP <61>/Eur. Ph. 2.6.12. Plate Count Method
Not detected CFU/g — >= 100
Endotoxin Analysis
Detailed Laboratory Data

Endotoxin Analysis

Test Result Unit Uncertainty Reporting Limit
Bacterial Endotoxin
USP<85>/ Eur. Ph. 2.6.14. Bacterial Endotoxin Chromogenic Test
< 0.001 EU/mg — > 0.5
Heavy Metals
Detailed Laboratory Data

Heavy Metals

Test Result Unit Uncertainty Reporting Limit
Arsenic
Elemental Impurities Screening
Not detected ppm — >= 1.5
Cadmium
Elemental Impurities Screening
Not detected ppm — >= 0.5
Cobalt
Elemental Impurities Screening
Not detected ppm — >= 25
Lead
Elemental Impurities Screening
Not detected ppm — >= 1.5
Nickel
Elemental Impurities Screening
Not detected ppm — >= 25
Quicksilver
Elemental Impurities Screening
Not detected ppm — >= 1.5
Vanadium
Elemental Impurities Screening
Not detected ppm — >= 25

Official Document

download report

The PDF remains the official laboratory document associated with this public verification record.

Open Official Report