Verified Laboratory Record

GLOW Blend

This public record confirms the current status and official metadata associated with the laboratory report below. The downloadable PDF remains the primary document of record for archive, review and verification.

Report ID

SYN-2026-005071
Verified

Official laboratory record

This record is active and matches the issued laboratory report.

Verification Summary

Official Record

Report ID
SYN-2026-005071
Status
Verified
Analysis Date
07 Sep 2026
Issued
09 Sep 2026
Verification Key
VK-K2CZ-LCZ3

Sample Information

Verified Sample

Sample
GLOW Blend
Strength
70mg
Batch
PC-GLW70-0930U
Cap / Crimp Color
Transparent Blue / Gold
Manufacturer
PepticoreAminos
Form
White powder in a glass vial
Sample Submission
Sample provided by customer
Received Date
01 Sep 2026
Client
www.pepticoreaminos.net

Analytical Results

Reported Values

Primary values from the official record
Identity
Glow Blend
Quantity
87.56mg

Methodology

Analysis Method

Standard Peptide Purity, Mass & Additional Testing

HPLC-UV: High-Performance Liquid Chromatography with Ultraviolet detection. Additional testing includes bioburden screening, endotoxin analysis and heavy metals assessment.

Authorization

Electronic Authorization

Electronically signed by Martin Saar
Date: 2026-09-09 11:59:47 UTC

Comments

Laboratory Notes

The applied RP-HPLC-UV method confirms that the sample meets the defined analytical specifications for identity, purity and impurity profile.

Supplemental Data

Technical Appendix

Expanded technical sections for reference
Blend Composition
Detailed Laboratory Data

Measured Blend Components

Component Measured Mass
Ghk-Cu (GHK Content) [Copper Content]
63.03mg (55.43mg) [7.60mg]
BPC-157
12.21mg
TB-500 (TB4)
12.32mg
Bioburden
Detailed Laboratory Data

Bioburden

Test Result Unit Uncertainty Reporting Limit
Total Aerobic Microbial Count
USP <61>/Eur. Ph. 2.6.12. Plate Count Method
Not detected CFU/g — >= 1000
Total Yeast and Mold Count
USP <61>/Eur. Ph. 2.6.12. Plate Count Method
Not detected CFU/g — >= 100
Endotoxin Analysis
Detailed Laboratory Data

Endotoxin Analysis

Test Result Unit Uncertainty Reporting Limit
Bacterial Endotoxin
USP<85>/ Eur. Ph. 2.6.14. Bacterial Endotoxin Chromogenic Test
< 0.001 EU/mg — > 0.5
Heavy Metals
Detailed Laboratory Data

Heavy Metals

Test Result Unit Uncertainty Reporting Limit
Arsenic
Elemental Impurities Screening
Not detected ppm — >= 1.5
Cadmium
Elemental Impurities Screening
Not detected ppm — >= 0.5
Cobalt
Elemental Impurities Screening
Not detected ppm — >= 25
Lead
Elemental Impurities Screening
Not detected ppm — >= 1.5
Nickel
Elemental Impurities Screening
Not detected ppm — >= 25
Quicksilver
Elemental Impurities Screening
Not detected ppm — >= 1.5
Vanadium
Elemental Impurities Screening
Not detected ppm — >= 25

Official Document

download report

The PDF remains the official laboratory document associated with this public verification record.

Open Official Report